SPN | 2412 |
---|---|
SP Name | Date format |
SP Description | Command sent to all CFs specifying the displayed format of the date. Value Meaning 0 ddmmyyyy 1 ddyyyymm 2 mmyyyydd 3 mmddyyyy 4 yyyymmdd 5 yyyyddmm 6–250 Reserved |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2018 |
SP Length | 8 bits |
Scaling | 1 count/bit |
Offset | 0 |
Data Range | 0 to 255 |
Operational Range | 0-5 |
Units | binary |
Slot Identifier | 120 |
Slot Name | SAEcb01 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 255 |
Length minimum (value only) | 8 |
Length maximum (value only) | 8 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | 2000-08-10 |
PG SP Mapping Created/Mod. Date | 2000-08-10 |