| PGN | 65048 |
|---|---|
| PG Label | Auxiliary valve 8 estimated flow |
| PG Acronym | AV08EF |
| PG Notes | Message that provides the estimated flow of auxiliary valve number 08. |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 254 |
| PS | 24 |
| Multipacket | No |
| Transmission Rate | 100 ms |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 7.1 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | 2011-02-03 |
| PG SP Mapping Created/Mod. Date | 2017-11-20 |
Linked SPNs
Displaying 1-7 of 7 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 1997 | Auxiliary valve number 08 extend port estimated flow | 1 | 8 bits | 1 %/bit | -125 | ![]() |
| 1998 | Auxiliary valve number 08 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | ![]() |
| 1999 | Auxiliary valve number 08 valve state | 3.1 | 4 bits | 16 states/4 bit | 0 | ![]() |
| 2262 | Auxiliary valve 08 fail safe mode | 3.7 | 2 bits | 4 states/2 bit | 0 | ![]() |
| 5177 | Auxiliary valve number 08 estimated flow limit status | 4.6 | 3 bits | 8 states/3 bit | 0 | ![]() |
| 5808 | Auxiliary valve 08 exit/reason code | 5.1 | 6 bits | 64 states/6 bit | 0 | ![]() |