| SPN | 2289 |
|---|---|
| SP Name | Auxiliary valve number 11 extend port estimated flow |
| SP Description | Value reported by the flow controller through the extend port of auxiliary valve 11 of a tractor, which could be based on the commanded position of the valve. Zero percent indicates no flow, 100 % indicates maximum flow, −100 % indicates maximum flow returning to the tractor through this port. Caution should be exercised when using this parameter in feedback control systems because this parameter is estimated and not measured. |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | 2015 |
| SP Length | 8 bits |
| Scaling | 1 %/bit |
| Offset | -125 |
| Data Range | -125 to 125 % |
| Operational Range | Not set |
| Units | % |
| Slot Identifier | 45 |
| Slot Name | SAEpc05 |
| SP Type | Estimated |
| SP Reference | Not set |
| Scale Factor (value only) | 1 |
| Offset (value only) | -125 |
| Range maximum (value only) | 125 |
| Length minimum (value only) | 8 |
| Length maximum (value only) | 8 |
| SP Document | ISO 11783-7 |
| PG Created or Modified Date | 2011-02-03 |
| PG SP Mapping Created/Mod. Date | 2000-08-10 |