| PGN | 65057 |
|---|---|
| PG Label | Auxiliary valve 1 measured flow |
| PG Acronym | AV01MF |
| PG Notes | Message that provides the measurement of auxiliary valve number 01 . |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 254 |
| PS | 33 |
| Multipacket | No |
| Transmission Rate | 100 ms |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 8.6 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | Not set |
| PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-6 of 6 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 1911 | Auxiliary valve number 01 extend port measured flow | 1 | 8 bits | 1 %/bit | -125 | ![]() |
| 1912 | Auxiliary valve number 01 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | ![]() |
| 1916 | Auxiliary valve number 01 extend port pressure | 3-4 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 1917 | Auxiliary valve number 01 retract port pressure | 5-6 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 1918 | Auxiliary valve number 01 return port pressure | 7 | 8 bits | 16 kPa/bit | 0 | ![]() |
| 5162 | Auxiliary valve number 01 measured flow limit status | 8.6 | 3 bits | 8 states/3 bit | 0 | ![]() |