SPN | 5725 |
---|---|
SP Name | Guidance system command exit/reason code |
SP Description | This parameter is used to indicate why the guidance system cannot currently accept remote commands or has most recently stopped accepting remote commands. Value Meaning 000000 No reason/all clear 000001 Required level of operator presence/awareness not detected 000010 Implement released control of function 000011 Operator override of function 000100 Operator control not in valid position 000101 Remote command timeout 000110 Remote command out of range/invalid 000111 Function not calibrated 001000 Operator control fault 001001 Function fault 001010 to 010011 Reserved 010100 Hydraulic oil level too low 010101 Hydraulic oil temperature too low 010110 Vehicle transmission gear does not allow remote commands (park, etc.) 010111 Vehicle speed too low 011000 Vehicle speed too high 011001 Alternate guidance system active 011010 Control unit in diagnostic mode 011011 to 110000 Reserved 110001 to 111101 Manufacturer specific 111110 Error 111111 Not available (parameter not supported) |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2018 |
SP Length | 6 bits |
Scaling | 64 states/6 bit |
Offset | 0 |
Data Range | 0 to 63 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 91 |
Slot Name | SAEbs06 |
SP Type | Measured |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 63 |
Length minimum (value only) | 6 |
Length maximum (value only) | 6 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |