| PGN | 65078 |
|---|---|
| PG Label | Auxiliary valve 6 command |
| PG Acronym | AV06C |
| PG Notes | Message that provides control of the flow through the auxiliary valve number 6. |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 254 |
| PS | 54 |
| Multipacket | No |
| Transmission Rate | 100 ms when active |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 4.1 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | 2015-05-07 |
| PG SP Mapping Created/Mod. Date | 2015-05-07 |
Linked SPNs
Displaying 1-5 of 5 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 1979 | Auxiliary valve number 6 port flow — Command | 1 | 8 bits | 0.4 %/bit | 0 | ![]() |
| 7878 | Auxiliary valve number 6 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | ![]() |
| 1980 | Auxiliary valve number 6 state — Command | 3.1 | 4 bits | 16 states/4 bit | 0 | ![]() |
| 1981 | Auxiliary valve number 6 fail safe mode — Command | 3.7 | 2 bits | 4 states/2 bit | 0 | ![]() |
| 7862 | Auxiliary valve number 6 port flow — Extended Resolution Command | 4-5 | 16 bits | 0.0015625 %/bit | 0 | ![]() |