PGN | 53248 |
---|---|
PG Label | Background lighting level command |
PG Acronym | CL |
PG Notes | Message used to control the state of all background lighting functions such as instruments and switches. It shall be sent at each change of the background lighting level, with a maximum period of 5 s between messages. |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 208 |
PS | DA |
Multipacket | No |
Transmission Rate | On change of background lighting level. A maximum period of 5 s between messages. |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 1.1 |
PG Document | J1939DA |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |