SPN9727
SP NameGeneral-purpose valve port flow - Extended Resolution Command
SP DescriptionCommand for setting the flow through the extend or retract port of a general-purpose valve, expressed as a percentage of full flow.

0 % indicates no flow, 100 % indicates maximum flow; the flow returns to the tractor through the opposite port.

The low resolution parameter shall always be set to a value representing the current status of the valve. When this parameter contains “not available”, only the low resolution parameter is valid. When it is set to anything other than “not available”, it contains a valid value as well.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192018
SP Length16 bits
Scaling0.0015625 %/bit
Offset0
Data Range0 to 100.3984375 %
Operational Range0 to 100 %
Units%
Slot Identifier345
Slot NameSAEpc21
SP TypeCommand
SP ReferenceNot set
Scale Factor (value only)0.0015625
Offset (value only)0
Range maximum (value only)100.3984375
Length minimum (value only)16
Length maximum (value only)16
SP DocumentISO 11783-7
PG Created or Modified Date2002-08-09
PG SP Mapping Created/Mod. Date2017-11-20

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
50176General Purpose Valve commandView