SPN | 9727 |
---|---|
SP Name | General-purpose valve port flow - Extended Resolution Command |
SP Description | Command for setting the flow through the extend or retract port of a general-purpose valve, expressed as a percentage of full flow. 0 % indicates no flow, 100 % indicates maximum flow; the flow returns to the tractor through the opposite port. The low resolution parameter shall always be set to a value representing the current status of the valve. When this parameter contains “not available”, only the low resolution parameter is valid. When it is set to anything other than “not available”, it contains a valid value as well. |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2018 |
SP Length | 16 bits |
Scaling | 0.0015625 %/bit |
Offset | 0 |
Data Range | 0 to 100.3984375 % |
Operational Range | 0 to 100 % |
Units | % |
Slot Identifier | 345 |
Slot Name | SAEpc21 |
SP Type | Command |
SP Reference | Not set |
Scale Factor (value only) | 0.0015625 |
Offset (value only) | 0 |
Range maximum (value only) | 100.3984375 |
Length minimum (value only) | 16 |
Length maximum (value only) | 16 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | 2002-08-09 |
PG SP Mapping Created/Mod. Date | 2017-11-20 |