SPN9730
SP NameGeneral-purpose valve exit/reason code
SP DescriptionThis parameter is used to indicate why the general purpose valve cannot accept remote commands or has most recently stopped accepting remote commands.

Data length: 5 bits

Value Meaning
00000 No reason/all clear
00001 Required level of operator presence/awareness not detected
00010 Implement released control of function
00011 Operator override of function
00100 Operator control not in valid position
00101 Remote command timeout
00110 Remote command out of range/invalid
00111 Function not calibrated
01000 Operator control fault
01001 Function fault
01010 to 01111 Reserved
10000 Hydraulic oil level too low
10001 Valve locked out
10010 to 11101 Manufacturer specific
11110 Error
11111 Not available (parameter not supported)
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192018
SP Length5 bits
Scaling32 states/5 bit
Offset0
Data Range0 to 31
Operational RangeNot set
Unitsbit
Slot Identifier90
Slot NameSAEbs05
SP TypeEstimated
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)31
Length minimum (value only)5
Length maximum (value only)5
SP DocumentISO 11783-7
PG Created or Modified Date2002-08-09
PG SP Mapping Created/Mod. Date2017-11-20

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
50688General Purpose Valve estimated flowView