| PGN | 50176 |
|---|---|
| PG Label | General Purpose Valve command |
| PG Acronym | GPV3 |
| PG Notes | This message provides control of the flow through a general purpose valve. |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 196 |
| PS | DA |
| Multipacket | No |
| Transmission Rate | 100 ms when active |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 3.1 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | Not set |
| PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-4 of 4 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 2944 | General-purpose valve port flow - Command | 1 | 8 bits | 0.4 %/bit | 0 | ![]() |
| 2933 | General-purpose valve state - Command | 3.1 | 4 bits | 16 states/4 bit | 0 | ![]() |
| 2935 | General-purpose value fail safe mode - Command | 3.7 | 2 bits | 4 states/2 bit | 0 | ![]() |
| 9727 | General-purpose valve port flow - Extended Resolution Command | 4-5 | 16 bits | 0.0015625 %/bit | 0 | ![]() |