| SPN | 2940 |
|---|---|
| SP Name | General-purpose valve retract port estimated flow |
| SP Description | The value reported by the controller of flow through the retract port of a general-purpose valve, which could be based on the commanded position of the valve. Zero percent indicates no flow, 100 % indicates maximum flow, −100 % indicates maximum flow returning to the valve through this port. Caution should be exercised when using this parameter in feedback control systems because this parameter is estimated and not measured. |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | 2015 |
| SP Length | 8 bits |
| Scaling | 1 %/bit |
| Offset | -125 % |
| Data Range | -125 to 125 % |
| Operational Range | -100 to 100 % |
| Units | % |
| Slot Identifier | 45 |
| Slot Name | SAEpc05 |
| SP Type | Measured |
| SP Reference | Not set |
| Scale Factor (value only) | 1 |
| Offset (value only) | -125 |
| Range maximum (value only) | 125 |
| Length minimum (value only) | 8 |
| Length maximum (value only) | 8 |
| SP Document | ISO 11783-7 |
| PG Created or Modified Date | 2002-08-09 |
| PG SP Mapping Created/Mod. Date | 2002-08-09 |