SPN5818
SP NameMachine selected speed exit/reason code
SP DescriptionThis parameter is used to indicate why the vehicle speed control unit cannot currently accept remote commands or has most recently stopped accepting remote commands.

Value      Meaning
000000   No reason/all clear
000001   Required level of operator presence/awareness not detected
000010   Implement released control of function
000011   Operator override of function
000100   Operator control not in valid position
000101   Remote command timeout
000110   Remote command out of range/invalid
000111   Function not calibrated
001000   Operator control fault
001001   Function fault
001010 to 010101   Reserved
010110   Vehicle transmission gear does not allow remote commands (park, etc.)
010111 to 110000   Reserved
110001 to 111101   Manufacturer specific
111110   Error
111111   Not available (parameter not supported)
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length6 bits
Scaling64 states/6 bit
Offset0
Data Range0 to 63
Operational RangeNot set
Unitsbit
Slot Identifier91
Slot NameSAEbs06
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)63
Length minimum (value only)6
Length maximum (value only)6
SP DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
61474Machine Selected SpeedView