SPN13219
SP NameTIM connection version error code
SP DescriptionContains an information about the reason why a connection between TIM server and TIM client is not possible at this point in time. Set to 'no error' if a valid TIM connection version got established.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/2019Not set
SP Length8
Scaling1 count/bit
Offset0
Data Range0 - no error 1 - TIM server and TIM client version are incompatible 2 - TIM server does not have available connection slots 3 to 255 Reserved
Operational RangeNot set
Unitscount
Slot IdentifierNot set
Slot NameNot set
SP TypeEnumeration
SP ReferenceNot set
Scale Factor (value only)Not set
Offset (value only)Not set
Range maximum (value only)Not set
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-1
PG Created or Modified Date2016-11-17
PG SP Mapping Created/Mod. Date2024-03-06

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
8960Tractor Implement Management (TIM) Server to TIM ClientView