SPN | 8805 |
SP Name | Auxiliary Valve 27 Flow Request |
SP Description | This parameter is used to report the flow request of auxiliary valve number 27 |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | Not set |
SP Length | 16 bits |
Scaling | 0.004 % flow/bit |
Offset | -128.512 |
Data Range | -128.512 to 128.508 % |
Operational Range | -128.512 to 128.508 % |
Units | % |
Slot Identifier | 497 |
Slot Name | SAEpc28 |
SP Type | Measured |
SP Reference | Not set |
Scale Factor (value only) | 0.004 |
Offset (value only) | -128.512 |
Range maximum (value only) | 128.508 |
Length minimum (value only) | 16 |
Length maximum (value only) | 16 |
SP Document | ISO 11783-1 |
PG Created or Modified Date | 2016-11-17 |
PG SP Mapping Created/Mod. Date | 2017-02-21 |
Linked PGNs
Displaying 1-2 of 2 results.
PGN | PG Label | |
9216 | Tractor Implement Management (TIM) Client to TIM Server | |
15616 | Tractor Implement Management (TIM) Client to TIM Server - Control Status | |
509934