| PGN | 1792 |
|---|---|
| PG Label | General Purpose Valve Pressure |
| PG Acronym | GPV4 |
| PG Notes | The measured load sense pressure and pilot pressure of a valve. May also include the load sense and supply pressure for a valve assembly, when available. |
| Pgn Notes | Not set |
| EDP | 0 |
| DP | 0 |
| PF | 7 |
| PS | DA |
| Multipacket | No |
| Transmission Rate | 100 ms when active |
| PG Data Length | 8 |
| Default Priority | 6 |
| PG Reference | Not set |
| Sp Start Bit | 8.1 |
| PG Document | J1939DA |
| PG Created or Modified Date | 2006-05-11 |
| PG SP Mapping Created/Mod. Date | 2022-05-19 |
Linked SPNs
Displaying 1-5 of 5 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 4086 | General-purpose valve load sense pressure | 1-2 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 4087 | General-purpose valve pilot pressure | 3 | 8 bits | 16 kPa/bit | 0 | ![]() |
| 4088 | General-purpose valve assembly load sense pressure | 4-5 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 4089 | General-purpose valve assembly supply pressure | 6-7 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 22130 | Valve Pilot Pressure Switch | 8.1 | 2 bits | 4 states | 0 | ![]() |