| PGN | 15360 |
|---|---|
| PG Label | Tractor Implement Management (TIM) Server to TIM Client - Control Status |
| PG Acronym | TIM12_CS |
| PG Notes | Tractor Implement Management (TIM) Server to TIM Client Control Status, Operation and Function messages. The first byte of the PGN contains the Message code or the TIM function ID. |
| Pgn Notes | Not set |
| EDP | 0 |
| DP | 0 |
| PF | 60 |
| PS | DA |
| Multipacket | Yes |
| Transmission Rate | As Required |
| PG Data Length | Variable |
| Default Priority | 7 |
| PG Reference | Not set |
| Sp Start Bit | 5.1 |
| PG Document | ISO 11783-1 |
| PG Created or Modified Date | 2023-02-09 |
| PG SP Mapping Created/Mod. Date | 2024-03-06 |
Linked SPNs
Displaying 301-321 of 321 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 24700 | MSA connection version | 5.1 | 8 bits | 1 count/bit | 0 | ![]() |
| 8665 | Auxiliary Valve 1 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8666 | Auxiliary Valve 2 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8667 | Auxiliary Valve 3 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8668 | Auxiliary Valve 4 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8669 | Auxiliary Valve 5 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8670 | Auxiliary Valve 6 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8671 | Auxiliary Valve 7 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8672 | Auxiliary Valve 8 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8673 | Auxiliary Valve 9 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8674 | Auxiliary Valve 10 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8675 | Auxiliary Valve 11 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8676 | Auxiliary Valve 12 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8677 | Auxiliary Valve 13 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 8678 | Auxiliary Valve 14 Flow | 5.1 | 16 bits | 0.004 % flow/bit | -128.512 | ![]() |
| 23874 | Control Mode parametrization status values | 6 to 6+a-1 | Variable - 0 to 250 | Data Specific | Data Specific | ![]() |
| 24696 | Minimum MSA Server version | 6.1 | 8 bits | 1 count/bit | 0 | ![]() |
| 23868 | Front Hitch State | 7.1 | 4 bits | 16 states | 0 | ![]() |
| 23869 | Rear Hitch State | 7.1 | 4 bits | 16 states | 0 | ![]() |
| 23870 | Front Top Linkage State | 7.1 | 4 bits | 16 states | 0 | ![]() |
| 23871 | Rear Top Linkage State | 7.1 | 4 bits | 16 states | 0 | ![]() |