SPN | 23577 |
SP Name | TIM v2 Server to Client function ID / Message Code |
SP Description | This parameter acts as 1st multiplexer in the PGN. It allows to identify the message content being either one of the connection establishment or containing data for one specific TIM function. |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | Not set |
SP Length | 8 bits |
Scaling | 1 count/bit |
Offset | 0 |
Data Range | Function ID list:
00 - Auxiliary valve superset
01 to 32 - Auxiliary valve 1 to 32
33 to 48 - Electrical power outlet 1 to 16
49 to 62 - Reserved
63 - Electrical power outlet superset
64 - Front PTO
65 - Rear PTO
66 - Front hitch
67 - Rear hitch
68 - Vehi |
Operational Range | 0 to 255 |
Units | count |
Slot Identifier | 133 |
Slot Name | SAEct03 |
SP Type | Count (no error, N/A) |
SP Reference | Not set |
Scale Factor (value only) | Not set |
Offset (value only) | Not set |
Range maximum (value only) | 255 |
Length minimum (value only) | 8 |
Length maximum (value only) | 8 |
SP Document | ISO 11783-1 |
PG Created or Modified Date | 2023-02-09 |
PG SP Mapping Created/Mod. Date | 2024-03-06 |
Linked PGNs
Displaying 1-1 of 1 result.
PGN | PG Label | |
15360 | Tractor Implement Management (TIM) Server to TIM Client - Control Status | |
883