SPN | 23888 |
SP Name | Number of TIM server functions assigned to CF to follow |
SP Description | This parameter is used to report the number of TIM functions assigned to the Control Function to follow in the message. |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | Not set |
SP Length | 1 byte |
Scaling | 1 byte per bit |
Offset | 0 byte |
Data Range | 0 to 250 |
Operational Range | Not set |
Units | byte |
Slot Identifier | 239 |
Slot Name | SAEby01 |
SP Type | Number of bytes |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 250 |
Length minimum (value only) | 8 |
Length maximum (value only) | 8 |
SP Document | ISO 11783-1 |
PG Created or Modified Date | 2024-03-06 |
PG SP Mapping Created/Mod. Date | 2024-08-15 |
Linked PGNs
Displaying 1-1 of 1 result.
PGN | PG Label | |
15360 | Tractor Implement Management (TIM) Server to TIM Client - Control Status | |
907