Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 101-200 of 330 results.
Function NoMeaningValueMeaning 
  
27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentView
3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentView
4Aux-O functions(Byte 1) bits 4 to 8Reserved for ISO assignmentView
26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentView
28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentView
0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentView
13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentView
14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0001Front PTO disengagement is supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0000 0001Front PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0010Front PTO engagement CCW is supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0000 0010Front PTO engagement CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0100Front PTO engagement CW is supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0000 0100Front PTO engagement CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 1000Front PTO speed CCW is supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0000 1000Front PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0001 0000Front PTO speed CW is supportedView
15Tractor Implement Management (TIM) Server(Byte 10) 0001 0000Front PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) bits 6 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 10) bits 6 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0001Rear PTO disengagement is supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0000 0001Rear PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0010Rear PTO engagement CCW is supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0000 0010Rear PTO engagement CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0100Rear PTO engagement CW is supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0000 0100Rear PTO engagement CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 1000Rear PTO speed CCW is supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0000 1000Rear PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0001 0000Rear PTO speed CW is supportedView
15Tractor Implement Management (TIM) Server(Byte 11) 0001 0000Rear PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) bits 6 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 11) bits 6 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 12) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0001Front hitch motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 12) 0000 0001Front hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0010Front hitch position is supportedView
15Tractor Implement Management (TIM) Server(Byte 12) 0000 0010Front hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) bits 3 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 12) bits 3 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 13) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0001Rear hitch motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 13) 0000 0001Rear hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0010Rear hitch position is supportedView
15Tractor Implement Management (TIM) Server(Byte 13) 0000 0010Rear hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) bits 3 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 13) bits 3 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0100Vehicle Speed start motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0100Vehicle Speed start motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 1000Vehicle Speed stop motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 1000Vehicle Speed stop motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0100 0000Vehicle Speed change direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0100 0000Vehicle Speed change direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 1000 0000Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 14) 1000 0000Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 15) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 15) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 15) 0000 0001Guidance curvature is supportedView
15Tractor Implement Management (TIM) Server(Byte 15) 0000 0001Guidance curvature is supportedView
16Tractor Implement Management (TIM) Client(Byte 15) bits 2 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 15) bits 2 to 8Reserved for ISO assignmentView
5Aux-N inputs(Byte 2) 0000 0000No options for this option byte supportedView
6Aux-N functions(Byte 2) 0000 0000No options for this option byte supportedView
9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0000No options for this option byte supportedView
15Tractor Implement Management (TIM) Server(Byte 2) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedView
5Aux-N inputs(Byte 2) 0000 0001Supports type 8 functionView
6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionView
9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0001Polygon-based prescription maps are supportedView
15Tractor Implement Management (TIM) Server(Byte 2) 0000 0001Aux valve 5 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0001Aux valve 5 state is supportedView
5Aux-N inputs(Byte 2) 0000 0010Supports type 9 functionView
6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionView
15Tractor Implement Management (TIM) Server(Byte 2) 0000 0010Aux valve 5 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0010Aux valve 5 flow is supportedView
5Aux-N inputs(Byte 2) 0000 0100Supports type 10 functionView
6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionView
15Tractor Implement Management (TIM) Server(Byte 2) 0000 0100Aux valve 6 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0100Aux valve 6 state is supportedView
5Aux-N inputs(Byte 2) 0000 1000Supports type 11 functionView
6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionView
15Tractor Implement Management (TIM) Server(Byte 2) 0000 1000Aux valve 6 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 1000Aux valve 6 flow is supportedView
5Aux-N inputs(Byte 2) 0001 0000Supports type 12 functionView