Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 323 results.
Function NoMeaningValueMeaning 
  
26ISOBUS System Information (INFO) Server00000010(1) Support of diagnostic data exportView
26ISOBUS System Information (INFO) Server00000001(1) Support of onboard visualizationView
26ISOBUS System Information (INFO) Server00000100(1) Support of CAN trace possibilityView
26ISOBUS System Information (INFO) Server00001000 to 10000000(1) Reserved for ISO assignmentView
26ISOBUS System Information (INFO) Server00000000(1) No options for this option byte supportedView
25Datalogger (LOG) Client00000001 to 10000000(1) Reserved for ISO assignmentView
25Datalogger (LOG) Client00000000(1) No optionsView
24Datalogger (LOG) Server00000000(1) No options for this option byte supportedView
24Datalogger (LOG) Server00000001(1) Data logger (LOG) service type supports FMIS interfaceView
24Datalogger (LOG) Server00000010 to 10000000(1) Reserved for ISO assignmentView
22ISOBUS Shortcut Button (ISB) Client00000001 to 10000000(1) Reserved for ISO assignmentView
22ISOBUS Shortcut Button (ISB) Client00000000(1) No optionsView
21ISOBUS Shortcut Button (ISB) Server00000000(1) No optionsView
21ISOBUS Shortcut Button (ISB) Server00000001 to 10000000(1) Reserved for ISO assignmentView
20Sequence Controller (SQC) Client00000001 to 10000000(1) Reserved for ISO assignmentView
20Sequence Controller (SQC) Client00000000(1) No optionsView
19Sequence Controller (SQC) Server00000000(1) No optionsView
19Sequence Controller (SQC) Server00000001 to 10000000(1) Reserved for ISO assignmentView
18File Server Client00000001 to 10000000(1) Reserved for ISO assignmentView
18File Server Client00000000(1) No optionsView
17File Server00000000(1) No optionsView
17File Server00000001 to 10000000(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 8) 00010000(1) Aux valve 31 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00000001(1) Aux valve 17 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 00000001(1) Front hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00100000(1) Aux valve 23 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 10000000(1) Aux valve 20 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 00000001(1) Front PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 10000000(1) Aux valve 32 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 00000001(1) Aux valve 13 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00100000(1) Aux valve 11 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00001000(1) Aux valve 18 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 01000000(1) Aux valve 8 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00000010(1) Aux valve 17 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00000010(1) Aux valve 9 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 00000100(1) Rear PTO engagement CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 00000001(1) Rear PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00001000(1) Aux valve 30 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 00000010(1) Front hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 00000100(1) Vehicle Speed start motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 00000001(1) Vehicle Speed in forward direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 00001000(1) Front PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00001000(1) Aux valve 10 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 00001000(1) Aux valve 14 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00001000(1) Aux valve 26 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00000001(1) Aux valve 21 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00010000(1) Aux valve 23 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 01000000(1) Aux valve 28 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00000100(1) Aux valve 26 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00001000(1) Aux valve 22 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00010000(1) Aux valve 19 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00000100(1) Aux valve 30 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 00100000 to 10000000(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) 00001000(1) Rear PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 00000010(1) Rear PTO engagement CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 00010000(1) Front PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00000010(1) Aux valve 29 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 00000001(1) Rear hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 00000100 to 10000000(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) 00100000 to 10000000(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 13) 00000100 to 10000000(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 14) 00000010(1) Vehicle Speed in reverse direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 00000010(1) Rear hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 00010000(1) Rear PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00000001(1) Aux valve 29 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 01000000(1) Aux valve 12 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00010000(1) Aux valve 11 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00000001(1) Aux valve 9 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 00010000(1) Aux valve 15 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 10000000(1) Aux valve 12 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00000100(1) Aux valve 18 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 10000000(1) Aux valve 16 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 01000000(1) Aux valve 20 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 5) 00100000(1) Aux valve 19 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 01000000(1) Aux valve 16 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 4) 00100000(1) Aux valve 15 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00000010(1) Aux valve 21 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 00000100(1) Aux valve 22 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 01000000(1) Aux valve 24 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 6) 10000000(1) Aux valve 24 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00000001(1) Aux valve 25 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00000010(1) Aux valve 25 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00010000(1) Aux valve 27 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 7) 00100000(1) Aux valve 27 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00000000(1) No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 00100000(1) Aux valve 31 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 01000000(1) Aux valve 32 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 9) bits 1 to 6, values 0 to 32(1) Amount of supported auxiliary valvesView
16Tractor Implement Management (TIM) Client(Byte 9) bits 7 to 8(1) Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 10) 00000010(1) Front PTO engagement CCW is supportedView