Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 330 results.
Function NoMeaningValueMeaning 
  
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlView
28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentView
27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedView
27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityView
26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentView
25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsView
25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedView
24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceView
24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentView
22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsView
22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsView
21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsView
20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsView
19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
18File Server Client(Byte 1) 0000 0000No optionsView
18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
17File Server(Byte 1) 0000 0000No optionsView
17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 7) 1000 0000Aux valve 28 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0000 0001Aux valve 29 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0000 0010Aux valve 29 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0000 0100Aux valve 30 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0000 1000Aux valve 30 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0001 0000Aux valve 31 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0010 0000Aux valve 31 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 0100 0000Aux valve 32 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 8) 1000 0000Aux valve 32 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 9) bits 1 to 6, values 0 to 32Amount of supported auxiliary valvesView
16Tractor Implement Management (TIM) Client(Byte 9) bits 7 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0001Front PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0010Front PTO engagement CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 0100Front PTO engagement CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0000 1000Front PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) 0001 0000Front PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 10) bits 6 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0001Rear PTO disengagement is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0010Rear PTO engagement CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 0100Rear PTO engagement CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0000 1000Rear PTO speed CCW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) 0001 0000Rear PTO speed CW is supportedView
16Tractor Implement Management (TIM) Client(Byte 11) bits 6 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0001Front hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) 0000 0010Front hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 12) bits 3 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0001Rear hitch motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) 0000 0010Rear hitch position is supportedView
16Tractor Implement Management (TIM) Client(Byte 13) bits 3 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0100Vehicle Speed start motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 1000Vehicle Speed stop motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0100 0000Vehicle Speed change direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 1000 0000Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 15) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 15) 0000 0001Guidance curvature is supportedView
16Tractor Implement Management (TIM) Client(Byte 15) bits 2 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0001Aux valve 1 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0010Aux valve 1 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 0100Aux valve 2 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0000 1000Aux valve 2 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0001 0000Aux valve 3 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0010 0000Aux valve 3 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 0100 0000Aux valve 4 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 1) 1000 0000Aux valve 4 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0001Aux valve 5 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0010Aux valve 5 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 0100Aux valve 6 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0000 1000Aux valve 6 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0001 0000Aux valve 7 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0010 0000Aux valve 7 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 0100 0000Aux valve 8 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 2) 1000 0000Aux valve 8 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0000 0000No options for this option byte supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0000 0001Aux valve 9 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0000 0010Aux valve 9 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0000 0100Aux valve 10 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0000 1000Aux valve 10 flow is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0001 0000Aux valve 11 state is supportedView
16Tractor Implement Management (TIM) Client(Byte 3) 0010 0000Aux valve 11 flow is supportedView