Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 201-300 of 305 results.
Function No | Meaning | Value | Meaning | |
---|---|---|---|---|
15 | Tractor Implement Management Server | (Byte 12) 00000000 | (1) No options for this option byte supported | |
15 | Tractor Implement Management Server | (Byte 12) 00000001 | (1) Front hitch motion is supported | |
15 | Tractor Implement Management Server | (Byte 12) 00000010 | (1) Front hitch position is supported | |
15 | Tractor Implement Management Server | (Byte 12) 00000100 to 10000000 | (1) Reserved for ISO assignment | |
15 | Tractor Implement Management Server | (Byte 13) 00000000 | (1) No options for this option byte supported | |
15 | Tractor Implement Management Server | (Byte 13) 00000001 | (1) Rear hitch motion is supported | |
15 | Tractor Implement Management Server | (Byte 13) 00000010 | (1) Rear hitch position is supported | |
15 | Tractor Implement Management Server | (Byte 13) 00000100 to 10000000 | (1) Reserved for ISO assignment | |
15 | Tractor Implement Management Server | (Byte 14) 00000000 | (1) No options for this option byte supported | |
15 | Tractor Implement Management Server | (Byte 14) 00000001 | (1) Vehicle Speed in forward direction is supported | |
15 | Tractor Implement Management Server | (Byte 14) 00000010 | (1) Vehicle Speed in reverse direction is supported | |
15 | Tractor Implement Management Server | (Byte 14) 00000100 | (1) Vehicle Speed start motion is supported | |
15 | Tractor Implement Management Server | (Byte 14) 00001000 | (1) Vehicle Speed stop motion is supported | |
15 | Tractor Implement Management Server | (Byte 14) 00010000 | (1) Vehicle Speed forward set by server is supported | |
15 | Tractor Implement Management Server | (Byte 14) 00100000 | (1) Vehicle Speed reverse set by server is supported | |
15 | Tractor Implement Management Server | (Byte 14) 01000000 | (1) Vehicle Speed change direction is supported | |
15 | Tractor Implement Management Server | (Byte 14) 10000000 | (1) Reserved for ISO assignment | |
15 | Tractor Implement Management Server | (Byte 15) 00000000 | (1) No options for this option byte supported | |
15 | Tractor Implement Management Server | (Byte 15) 00000001 | (1) Guidance curvature is supported | |
15 | Tractor Implement Management Server | (Byte 15) 00000010 to 10000000 | (1) Reserved for ISO assignment | |
14 | Basic Tractor ECU implement (Client) | 00000000 | (1) TECU not meeting complete class 1 requirements | |
14 | Basic Tractor ECU implement (Client) | 00000001 | (1) Class 1, no options | |
14 | Basic Tractor ECU implement (Client) | 00000010 | (1) Class 2, no options | |
14 | Basic Tractor ECU implement (Client) | 00000100 | (1) Class required lighting (L) | |
14 | Basic Tractor ECU implement (Client) | 00001000 | (1) Navigation option (N) | |
14 | Basic Tractor ECU implement (Client) | 00010000 | (1) Front hitch option (F) | |
14 | Basic Tractor ECU implement (Client) | 00100000 | (1) Guidance option (G) | |
14 | Basic Tractor ECU implement (Client) | 01000000 | (1) Reserved for ISO assignment | |
14 | Basic Tractor ECU implement (Client) | 10000000 | (1) Reserved for ISO assignment | |
13 | Basic Tractor ECU (Server) | 00000000 | (1) TECU not meeting complete class 1 requirements | |
13 | Basic Tractor ECU (Server) | 00000001 | (1) Class 1, no options | |
13 | Basic Tractor ECU (Server) | 00000010 | (1) Class 2, no options | |
13 | Basic Tractor ECU (Server) | 00000100 | (1) Lighting option (L) | |
13 | Basic Tractor ECU (Server) | 00001000 | (1) Navigation option (N) | |
13 | Basic Tractor ECU (Server) | 00010000 | (1) Front hitch option (F) | |
13 | Basic Tractor ECU (Server) | 00100000 | (1) Guidance option (G) | |
13 | Basic Tractor ECU (Server) | 01000000 | (1) Reserved for ISO assignment | |
13 | Basic Tractor ECU (Server) | 10000000 | (1) Reserved for ISO assignment | |
12 | Task Controller Section Control Client | 1 to 255 | (1) Number of supported booms | |
12 | Task Controller Section Control Client | 1 to 255 | (2) Number of supported sections | |
11 | Task Controller Section Control Server | 1 to 255 | (1) Number of supported booms | |
11 | Task Controller Section Control Server | 1 to 255 | (2) Number of supported sections | |
10 | Task Controller Geo Client | 1 to 255 | (1) Number of control channels | |
9 | Task Controller Geo Server | 1 to 255 | (1) Number of control channels | |
9 | Task Controller Geo Server | 00000000 | (2) No options | |
9 | Task Controller Geo Server | 00000001 | (2) Polygon-based prescription maps are supported | |
9 | Task Controller Geo Server | 00000010 to 10000000 | (2) Reserved for ISO assignment | |
8 | Task Controller Basic Client | 00000000 | (1) No options | |
8 | Task Controller Basic Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | |
7 | Task Controller Basic Server | 00000000 | (1) No options | |
7 | Task Controller Basic Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | |
6 | Aux-N functions | 00000000 00000000 | (1) No options | |
6 | Aux-N functions | 00000000 00000001 | (1) Supports type 0 function | |
6 | Aux-N functions | 00000000 00000010 | (1) Supports type 1 function | |
6 | Aux-N functions | 00000000 00000100 | (1) Supports type 2 function | |
6 | Aux-N functions | 00000000 00001000 | (1) Supports type 3 function | |
6 | Aux-N functions | 00000000 00010000 | (1) Supports type 4 function | |
6 | Aux-N functions | 00000000 00100000 | (1) Supports type 5 function | |
6 | Aux-N functions | 00000000 01000000 | (1) Supports type 6 function | |
6 | Aux-N functions | 00000000 10000000 | (1) Supports type 7 function | |
6 | Aux-N functions | 00000001 00000000 | (1) Supports type 8 function | |
6 | Aux-N functions | 00000010 00000000 | (1) Supports type 9 function | |
6 | Aux-N functions | 00000100 00000000 | (1) Supports type 10 function | |
6 | Aux-N functions | 00001000 00000000 | (1) Supports type 11 function | |
6 | Aux-N functions | 00010000 00000000 | (1) Supports type 12 function | |
6 | Aux-N functions | 00100000 00000000 | (1) Supports type 13 function | |
6 | Aux-N functions | 01000000 00000000 | (1) Supports type 14 function | |
6 | Aux-N functions | 10000000 00000000 | (1) Reserved for ISO assignment | |
5 | Aux-N inputs | 00000000 00000000 | (1) No options | |
5 | Aux-N inputs | 00000000 00000001 | (1) Supports type 0 function | |
5 | Aux-N inputs | 00000000 00000010 | (1) Supports type 1 function | |
5 | Aux-N inputs | 00000000 00000100 | (1) Supports type 2 function | |
5 | Aux-N inputs | 00000000 00001000 | (1) Supports type 3 function | |
5 | Aux-N inputs | 00000000 00010000 | (1) Supports type 4 function | |
5 | Aux-N inputs | 00000000 00100000 | (1) Supports type 5 function | |
5 | Aux-N inputs | 00000000 01000000 | (1) Supports type 6 function | |
5 | Aux-N inputs | 00000000 10000000 | (1) Supports type 7 function | |
5 | Aux-N inputs | 00000001 00000000 | (1) Supports type 8 function | |
5 | Aux-N inputs | 00000010 00000000 | (1) Supports type 9 function | |
5 | Aux-N inputs | 00000100 00000000 | (1) Supports type 10 function | |
5 | Aux-N inputs | 00001000 00000000 | (1) Supports type 11 function | |
5 | Aux-N inputs | 00010000 00000000 | (1) Supports type 12 function | |
5 | Aux-N inputs | 00100000 00000000 | (1) Supports type 13 function | |
5 | Aux-N inputs | 01000000 00000000 | (1) Supports type 14 function | |
5 | Aux-N inputs | 10000000 00000000 | (1) Reserved for ISO assignment | |
4 | Aux-O functions | 00000000 | (1) No options | |
4 | Aux-O functions | 00000001 | (1) Supports type 0 function | |
4 | Aux-O functions | 00000010 | (1) Supports type 1 function | |
4 | Aux-O functions | 00000100 | (1) Supports type 2 function | |
4 | Aux-O functions | 00001000 to 10000000 | (1) Reserved for ISO assignment | |
3 | Aux-O inputs | 00000000 | (1) No options | |
3 | Aux-O inputs | 00000001 | (1) Supports type 0 function | |
3 | Aux-O inputs | 00000010 | (1) Supports type 1 function | |
3 | Aux-O inputs | 00000100 | (1) Supports type 2 function | |
3 | Aux-O inputs | 00001000 to 10000000 | (1) Reserved for ISO assignment | |
2 | Universal Terminal working set (Client) | 00000000 | (1) No options | |
2 | Universal Terminal working set (Client) | 00000001 to 10000000 | (1) Reserved for ISO assignment | |
1 | Universal Terminal (Server) | 00000000 | (1) No options | |
1 | Universal Terminal (Server) | 00000001 to 10000000 | (1) Reserved for ISO assignment | |
0 | Minimum Control Function | 00000000 | (1) No options (Option Number in brackets) |