PGN65095
PG LabelMaintain Power
PG AcronymMP
PG NotesMessage sent by any CF connected to the implement bus requesting that the Tractor ECU not switch off the power for 2 s after it has received the wheel-based speed and distance message indicating that the ignition has been switched off. The message also includes the connected implement(s) operating state.
Pgn Notes-
EDP0
DP0
PF254
PS71
MultipacketNo
Transmission RateAs required after receiving the message indicating that the ignition switch has changed from the ON state to the OFF state, or on change of state of parameters.
PG Data Length8
Default Priority6
PG ReferenceNot set
Sp Start Bit2.7
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-6 of 6 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1868Maintain Acuator Power1.52 bits4 states/2 bit0View
1867Maintain ECU Power1.72 bits4 states/2 bit0View
7447Implement in-work state2.12 bits4 states/2 bit0View
1871Implement ready-to-work state2.32 bits4 states/2 bit0View
1870Implement Park state2.52 bits4 states/2 bit0View
1869Implement Transport state2.72 bits4 states/2 bit0View