PGN | 65095 |
PG Label | Maintain Power |
PG Acronym | MP |
PG Notes | Message sent by any CF connected to the implement bus requesting that the Tractor ECU not switch off the power for 2 s after it has received the wheel-based speed and distance message indicating that the ignition has been switched off. The message also includes the connected implement(s) operating state. |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 71 |
Multipacket | No |
Transmission Rate | As required after receiving the message indicating that the ignition switch has changed from the ON state to the OFF state, or on change of state of parameters. |
PG Data Length | 8 |
Default Priority | 6 |
PG Reference | Not set |
Sp Start Bit | 2.7 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | 2000-08-10 |
PG SP Mapping Created/Mod. Date | 2000-08-10 |
Linked SPNs