SPN | 1865 |
---|---|
SP Name | Key switch state |
SP Description | Indicates the key switch state of the tractor or power unit. This does not indicate unforeseen power interruptions such as those caused by starting the engine. Value Meaning 00 Key switch Off 01 Key switch not Off 10 Error indication 11 Not available |
Sp Notes | Not set |
Has Attachment | no |
SP Historical Remarks | - |
SP Historical Attachment | no |
From 2015/2019 | 2015 |
SP Length | 2 bits |
Scaling | 4 states/2 bit |
Offset | 0 |
Data Range | 0 to 3 |
Operational Range | Not set |
Units | bit |
Slot Identifier | 87 |
Slot Name | SAEbs02 |
SP Type | Measured |
SP Reference | Not set |
Scale Factor (value only) | 1 |
Offset (value only) | 0 |
Range maximum (value only) | 3 |
Length minimum (value only) | 2 |
Length maximum (value only) | 2 |
SP Document | ISO 11783-7 |
PG Created or Modified Date | 2000-08-10 |
PG SP Mapping Created/Mod. Date | 2000-08-10 |