PGN | 44032 |
---|---|
PG Label | Agricultural Guidance Machine Info |
PG Acronym | GMS |
PG Notes | This message provides feedback to interface automatic guidance control systems from machine steering systems. It provides information and status from the steering control system to the guidance system. |
Pgn Notes | Not set |
EDP | 0 |
DP | 0 |
PF | 172 |
PS | DA |
Multipacket | No |
Transmission Rate | 100 ms |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 3.5 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-8 of 8 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
5238 | Estimated curvature | 1-2 | 16 bits | 0.25 km-1/bit | -8032 | |
5243 | Mechanical system lockout | 3.1 | 2 bits | 4 states/2 bit | 0 | |
5242 | Guidance steering system readiness | 3.3 | 2 bits | 4 states/2 bit | 0 | |
5241 | Steering input position status | 3.5 | 2 bits | 4 states/2 bit | 0 | |
5240 | Request reset command status | 3.7 | 2 bits | 4 states/2 bit | 0 | |
5726 | Guidance Limit Status | 4.6 | 3 bits | 8 states/3 bit | 0 | |
5725 | Guidance system command exit/reason code | 5.1 | 6 bits | 64 states/6 bit | 0 | |
9726 | Guidance system Remote Engage Switch Status | 5.7 | 2 bits | 4 states/2 bit | 0 |