| PGN | 65093 |
|---|---|
| PG Label | Primary or Rear Hitch Status |
| PG Acronym | RHS |
| PG Notes | Message that provides the measurement of the current rear-hitch parameters. |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 254 |
| PS | 69 |
| Multipacket | No |
| Transmission Rate | 100 ms |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 2.4 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | Not set |
| PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-6 of 6 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 1873 | Rear Hitch Position | 1 | 8 bits | 0.4 %/bit | 0 | ![]() |
| 5151 | Rear Hitch Position Limit status | 2.4 | 3 bits | 8 states/3 bit | 0 | ![]() |
| 1877 | Rear Hitch In-work Indication | 2.7 | 2 bits | 4 states/2 bit | 0 | ![]() |
| 1881 | Rear Nominal Lower Link Force | 3 | 8 bits | 0.8 %/bit | -100 | ![]() |
| 1879 | Rear Draft | 4-5 | 16 bits | 10 N/bit | -320000 | ![]() |
| 5819 | Rear hitch exit/reason code | 6.1 | 6 bits | 64 states/6 bit | 0 | ![]() |