PGN | 50176 |
---|---|
PG Label | General Purpose Valve command |
PG Acronym | GPV3 |
PG Notes | This message provides control of the flow through a general purpose valve. |
Pgn Notes | - |
EDP | 0 |
DP | 0 |
PF | 196 |
PS | DA |
Multipacket | No |
Transmission Rate | 100 ms when active |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 3.7 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |
Linked SPNs
Displaying 1-4 of 4 results.
SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
---|---|---|---|---|---|---|
2944 | General-purpose valve port flow - Command | 1 | 8 bits | 0.4 %/bit | 0 | |
2933 | General-purpose valve state - Command | 3.1 | 4 bits | 16 states/4 bit | 0 | |
2935 | General-purpose value fail safe mode - Command | 3.7 | 2 bits | 4 states/2 bit | 0 | |
9727 | General-purpose valve port flow - Extended Resolution Command | 4-5 | 16 bits | 0.0015625 %/bit | 0 |