SPN2935
SP NameGeneral-purpose value fail safe mode - Command
SP DescriptionCommand for setting the fail safe mode of a general-purpose valve.

Data length: 2 bits

Value Meaning
00 Block
01 Float
10 Reserved
11 Don't care
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length2 bits
Scaling4 states/2 bit
Offset0
Data Range0 to 3
Operational RangeNot set
Unitsbit
Slot Identifier87
Slot NameSAEbs02
SP TypeCommand
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)0
Range maximum (value only)3
Length minimum (value only)2
Length maximum (value only)2
SP DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
50176General Purpose Valve commandView