| PGN | 50432 |
|---|---|
| PG Label | General Purpose Valve measured flow |
| PG Acronym | GPV2 |
| PG Notes | This message provides the measured flow of a general-purpose valve. |
| Pgn Notes | - |
| EDP | 0 |
| DP | 0 |
| PF | 197 |
| PS | DA |
| Multipacket | No |
| Transmission Rate | 100 ms |
| PG Data Length | 8 |
| Default Priority | 3 |
| PG Reference | Not set |
| Sp Start Bit | 3.1 |
| PG Document | ISO 11783-7 |
| PG Created or Modified Date | 2002-08-09 |
| PG SP Mapping Created/Mod. Date | 2002-08-09 |
Linked SPNs
Displaying 1-6 of 6 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 2937 | General-purpose valve extend port measured flow | 1 | 8 bits | 1 %/bit | -125 % | ![]() |
| 2938 | General-purpose valve retract port measured flow | 2 | 8 bits | 1 %/bit | -125 % | ![]() |
| 2941 | General-purpose valve extend port pressure | 3-4 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 2942 | General-purpose valve retract port pressure | 5-6 | 16 bits | 5 kPa/bit | 0 | ![]() |
| 2943 | General-purpose valve return port pressure | 7 | 8 bits | 16 kPa/bit | 0 | ![]() |
| 5192 | General-purpose valve measured limit status | 8.6 | 3 bits | 8 states/3 bit | 0 | ![]() |