Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 330 results.
Function NoMeaningValueMeaning 
  
16Tractor Implement Management (TIM) Client(Byte 14) 0000 1000Vehicle Speed stop motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 1000Vehicle Speed stop motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0100Vehicle Speed start motion is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0100Vehicle Speed start motion is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedView
16Tractor Implement Management (TIM) Client(Byte 14) 0100 0000Vehicle Speed change direction is supportedView
15Tractor Implement Management (TIM) Server(Byte 14) 0100 0000Vehicle Speed change direction is supportedView
0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationView
0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination View
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlView
13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsView
14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsView
5Aux-N inputs(Byte 2) 0000 0010Supports type 9 functionView
6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionView
5Aux-N inputs(Byte 2) 0000 0001Supports type 8 functionView
6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionView
5Aux-N inputs(Byte 1) 1000 0000Supports type 7 functionView
6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionView
5Aux-N inputs(Byte 1) 0100 0000Supports type 6 functionView
6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionView
5Aux-N inputs(Byte 1) 0010 0000Supports type 5 functionView
6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionView
5Aux-N inputs(Byte 1) 0001 0000Supports type 4 functionView
6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionView
5Aux-N inputs(Byte 1) 0000 1000Supports type 3 functionView
6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionView
3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionView
4Aux-O functions(Byte 1) 0000 0100Supports type 2 functionView
5Aux-N inputs(Byte 1) 0000 0100Supports type 2 functionView
6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionView
5Aux-N inputs(Byte 2) 0100 0000Supports type 14 functionView
6Aux-N functions(Byte 2) 0100 0000Supports type 14 functionView
5Aux-N inputs(Byte 2) 0010 0000Supports type 13 functionView
6Aux-N functions(Byte 2) 0010 0000Supports type 13 functionView
5Aux-N inputs(Byte 2) 0001 0000Supports type 12 functionView
6Aux-N functions(Byte 2) 0001 0000Supports type 12 functionView
5Aux-N inputs(Byte 2) 0000 1000Supports type 11 functionView
6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionView
5Aux-N inputs(Byte 2) 0000 0100Supports type 10 functionView
6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionView
3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionView
4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionView
5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionView
6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionView
3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionView
4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionView
5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionView
6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationView
0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerView
0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportView
26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityView
28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersView
0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentView
1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 9) bits 7 to 8Reserved for ISO assignmentView
3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 10) bits 6 to 8Reserved for ISO assignmentView
4Aux-O functions(Byte 1) bits 4 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) bits 6 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 12) bits 3 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 13) bits 3 to 8Reserved for ISO assignmentView
5Aux-N inputs(Byte 2) bit 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 14) 1000 0000Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 15) bits 2 to 8Reserved for ISO assignmentView
17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
6Aux-N functions(Byte 2) bit 8Reserved for ISO assignmentView
22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentView
25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentView
9Task Controller Geo (TC-GEO) Server(Byte 2) bits 2 to 8Reserved for ISO assignmentView
26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentView
27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentView
28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentView
13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentView
14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 9) bits 7 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 10) bits 6 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 11) bits 6 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 12) bits 3 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 13) bits 3 to 8Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 14) 1000 0000Reserved for ISO assignmentView
15Tractor Implement Management (TIM) Server(Byte 15) bits 2 to 8Reserved for ISO assignmentView
16Tractor Implement Management (TIM) Client(Byte 11) 0001 0000Rear PTO speed CW is supportedView