23573 | TIM v1 Server to Client function ID / Message Code | 1.1 | 8 bits | 1 count/bit | 0 | |
23575 | TIM v1 Client to Server function ID / Message Code | 1.1 | 8 bits | 1 count/bit | 0 | |
23577 | TIM v2 Server to Client function ID / Message Code | 1.1 | 8 bits | 1 count/bit | 0 | |
23580 | TIM v2 Client to Server function ID / Message Code | 1.1 | 8 bits | 1 count/bit | 0 | |
4313 | ISOBUS compliance test protocol publication year | 1.1 | 6 bits | 1 year/bit | 2000 | |
5199 | Process data command | 1.1 | 4 bits | 16 states/4 bit | 0 | |
5233 | Speed information - engine speed | 1.1 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed information - engine speed | 1.1 | 1 bit | 2 states/1 bit | 0 | |
2404 | Daytime running lights | 1.1 | 2 bits | 4 states/2 bit | 0 | |
2403 | Daytime running lights — Command | 1.1 | 2 bits | 4 states/2 bit | 0 | |
5233 | Speed information - ground based speed | 1.2 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed information - ground-based speed | 1.2 | 1 bit | 2 states/1 bit | 0 | |
5233 | Speed information - wheel based speed | 1.3 | 1 bit | 2 states/1 bit | 0 | |
5235 | Speed information - wheel-based speed | 1.3 | 1 bit | 2 states/1 bit | 0 | |
2352 | Alternate headlights | 1.3 | 2 bits | 4 states/2 bit | 0 | |
2351 | Alternate headlights — Command | 1.3 | 2 bits | 4 states/2 bit | 0 | |
5233 | Power management - maintain power | 1.4 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - maintain power | 1.4 | 1 bit | 2 states/1 bit | 0 | |
5204 | Tractor control mode command number 1 | 1.4 | 5 | 32 states/5 bit | 0 | |
5200 | Process data element number | 1.5 | 12 bits | | 0 | |
5233 | Power management - maximum time tractor power | 1.5 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - maximum time tractor power | 1.5 | 1 bit | 2 states/1 bit | 0 | |
2350 | Low-beam headlights | 1.5 | 2 bits | 4 states/2 bit | 0 | |
2349 | Low-beam headlights — Command | 1.5 | 2 bits | 4 states/2 bit | 0 | |
1868 | Maintain Acuator Power | 1.5 | 2 bits | 4 states/2 bit | 0 | |
5233 | Power management - key switch | 1.6 | 1 bit | 2 states/1 bit | 0 | |
5235 | Power management - key switch | 1.6 | 1 bit | 2 states/1 bit | 0 | |
5232 | Tractor ECU class request | 1.7 | 2 bits | 4 states/2 bit | 0 | |
5234 | Tractor ECU class response | 1.7 | 2 bits | 4 states/2 bit | 0 | |
2348 | High-beam headlights | 1.7 | 2 bits | 4 states/2 bit | 0 | |
2347 | High-beam headlights — Command | 1.7 | 2 bits | 4 states/2 bit | 0 | |
1867 | Maintain ECU Power | 1.7 | 2 bits | 4 states/2 bit | 0 | |
4314 | ISOBUS compliance test protocol revision | 1.7-2.1, 2.4-2.5 | 5 bits | 32 states/5 bit | 0 | |
7813 | Rear hitch pitch sensitivity | 2 | 8 bits | 0.4 %/bit | 0 | |
7801 | Front hitch pitch sensitivity | 2 | 8 bits | 0.4 %/bit | 0 | |
1875 | Rear hitch position — Command | 2 | 8 bits | 0.4 %/bit | 0 | |
1902 | Auxiliary valve 0 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1914 | Auxiliary valve number 01 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1926 | Auxiliary valve number 02 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1938 | Auxiliary valve number 03 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1950 | Auxiliary valve number 04 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1962 | Auxiliary valve number 05 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1974 | Auxiliary valve number 06 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1986 | Auxiliary valve number 07 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1998 | Auxiliary valve number 08 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2266 | Auxiliary valve number 09 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2278 | Auxiliary valve number 10 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2290 | Auxiliary valve number 11 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2302 | Auxiliary valve number 12 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2314 | Auxiliary valve number 13 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2326 | Auxiliary valve number 14 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
2338 | Auxiliary valve number 15 retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 | |
1900 | Auxiliary valve number 0 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1912 | Auxiliary valve number 01 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1924 | Auxiliary valve number 02 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1936 | Auxiliary valve number 03 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1948 | Auxiliary valve number 04 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1960 | Auxiliary valve number 05 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1972 | Auxiliary valve number 06 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1984 | Auxiliary valve number 07 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
1996 | Auxiliary valve number 08 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2264 | Auxiliary valve number 09 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2276 | Auxiliary valve number 10 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2288 | Auxiliary valve number 11 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2300 | Auxiliary valve number 12 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2312 | Auxiliary valve number 13 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2324 | Auxiliary valve number 14 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2336 | Auxiliary valve number 15 retract port measured flow | 2 | 8 bits | 1 %/bit | -125 | |
2938 | General-purpose valve retract port measured flow | 2 | 8 bits | 1 %/bit | -125 % | |
2940 | General-purpose valve retract port estimated flow | 2 | 8 bits | 1 %/bit | -125 % | |
960 | Minutes | 2 | 8 bits | 1 min/bit | 0 min | |
5728 | Drive strategy priority 2 | 2 | 8 bits | 256 states/8 bit | 0 | |
5734 | Drive strategy priority 2 request | 2 | 8 bits | 256 states/8 bit | 0 | |
234 | Software Identification | 2-N | Variable - up to 200 bytes followed by an "*" delimiter | ASCII | 0 | |
13212 | TIM server heartbeat counter | 2.1 | 8 bits | 1 count/bit | 0 | |
13219 | TIM connection version error code | 2.1 | 8 | 1 count/bit | 0 | |
13216 | TIM Boot time | 2.1 | 8 | 1 s per bit | 0 | |
13285 | TIM client heartbeat counter | 2.1 | 8 bits | 16 values/4 bit | 0 | |
23578 | TIM v2 Server to Client control mode | 2.1 | 4 | 16 values/4 bit | 0 | |
23581 | TIM v2 Client to Server control mode | 2.1 | 4 | 16 values/4 bit | 0 | |
9711 | Operator Presence state | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7872 | Auxiliary valve number 0 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7873 | Auxiliary valve number 1 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7874 | Auxiliary valve number 2 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7875 | Auxiliary valve number 3 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7876 | Auxiliary valve number 4 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7877 | Auxiliary valve number 5 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7878 | Auxiliary valve number 6 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7879 | Auxiliary valve number 7 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7880 | Auxiliary valve number 8 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7881 | Auxiliary valve number 9 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7882 | Auxiliary valve number 10 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7883 | Auxiliary valve number 11 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7884 | Auxiliary valve number 12 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7885 | Auxiliary valve number 13 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7886 | Auxiliary valve number 14 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7887 | Auxiliary valve number 15 Resolution mode — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
2388 | Tractor front fog lights | 2.1 | 2 bits | 4 states/2 bit | 0 | |
2387 | Tractor front fog lights — Command | 2.1 | 2 bits | 4 states/2 bit | 0 | |
7447 | Implement in-work state | 2.1 | 2 bits | 4 states/2 bit | 0 | |