PGNs and SPNs

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 901-1000 of 18552 results.
PGNPGN DescriptionSPNSPN Name 
 
49664See http://subs.sae.org//j1939_dl/ for details3048Engine Ignition Cycle CounterView
49664See http://subs.sae.org//j1939_dl/ for details3049OBD Monitoring Conditions Encountered CountsView
49664See http://subs.sae.org//j1939_dl/ for details3066SPN of Applicable System MonitorView
49664See http://subs.sae.org//j1939_dl/ for details3067Applicable System Monitor NumeratorView
49664See http://subs.sae.org//j1939_dl/ for details3068Applicable System Monitor DenominatorView
49920See http://subs.sae.org//j1939_dl/ for details3034DM22 Control Byte - Individual DTC Clear/Reset Control ByteView
49920See http://subs.sae.org//j1939_dl/ for details3035DM22 - Control Byte Specific Indicator For Individual DTC ClearView
49920See http://subs.sae.org//j1939_dl/ for details3036DM22 - SPNView
49920See http://subs.sae.org//j1939_dl/ for details3037DM22 - FMIView
50176Controls the flow through a general purpose valve2944port flow commandView
50176Controls the flow through a general purpose valve2933Valve state commandView
50176Controls the flow through a general purpose valve2935Valve fail safe mode commandView
50176Controls the flow through a general purpose valve9727Port Flow Extended Resolution commandView
50432Measurement of the flow through a general purpose valve2937extend port measured flowView
50432Measurement of the flow through a general purpose valve2938retract port measured flowView
50432Measurement of the flow through a general purpose valve2941extend port pressureView
50432Measurement of the flow through a general purpose valve2942retract port pressureView
50432Measurement of the flow through a general purpose valve2943return port pressureView
50432Measurement of the flow through a general purpose valve5192General purpose valve measured limit statusView
50688Estimated flow through of a general purpose valve2939extend port estimated flowView
50688Estimated flow through of a general purpose valve2940retract port estimated flowView
50688Estimated flow through of a general purpose valve2932Valve stateView
50688Estimated flow through of a general purpose valve2934Valve fail safe modeView
50688Estimated flow through of a general purpose valve5193General purpose valve estimated limit statusView
50688Estimated flow through of a general purpose valve9730General purpose valve exit/reason codeView
50688Estimated flow through of a general purpose valve9728extend port estimated flow (high resolution)View
50688Estimated flow through of a general purpose valve9729retract port estimated flow (high resolution)View
50944See document ISO 11783-3 for PGN details  View
51200See document ISO 11783-3 for PGN details  View
51456See http://subs.sae.org//j1939_dl/ for details2574Parameter Group Number (RQST2)View
51456See http://subs.sae.org//j1939_dl/ for details2575Use Transfer ModeView
51712See http://subs.sae.org//j1939_dl/ for details2552Parameter Group Number of Requested Information (XFER)View
51712See http://subs.sae.org//j1939_dl/ for details2553Length of data for the reported PGN (XFER)View
51712See http://subs.sae.org//j1939_dl/ for details2554Controller Application Identity (CAI)View
51712See http://subs.sae.org//j1939_dl/ for details2555Transfer DataView
51968See document ISO 11783-10 for PGN details5199Process data commandView
51968See document ISO 11783-10 for PGN details5200Process data element numberView
51968See document ISO 11783-10 for PGN details5201Process data data dictionary identifierView
51968See document ISO 11783-10 for PGN details5202Process data variable value View
52224Message allows the system to adapt the network bandwidth to the needs of the user of messages.  PGN of the requestView
52224Message allows the system to adapt the network bandwidth to the needs of the user of messages. 2418Repetition Rate ParameterView
52480See http://subs.sae.org//j1939_dl/ for details  View
52736See http://subs.sae.org//j1939_dl/ for details  View
52992See http://subs.sae.org//j1939_dl/ for details1784Engine Speed Limit Request - Minimum Continuous
52992See http://subs.sae.org//j1939_dl/ for details1785Engine Speed Limit Request - Maximum Continuous
52992See http://subs.sae.org//j1939_dl/ for details1786Engine Torque Limit Request - Minimum Continuous
52992See http://subs.sae.org//j1939_dl/ for details1787Engine Torque Limit Request - Maximum Continuous
52992See http://subs.sae.org//j1939_dl/ for details1788Minimum Continuous Retarder Speed Limit Request
52992See http://subs.sae.org//j1939_dl/ for details1789Maximum Continuous Retarder Speed Limit Request
52992See http://subs.sae.org//j1939_dl/ for details1790Minimum Continuous Retarder Torque Limit Request
52992See http://subs.sae.org//j1939_dl/ for details1791Maximum Continuous Retarder Torque Limit Request
53248See http://subs.sae.org//j1939_dl/ for details1487Illumination Brightness Percent
53248See http://subs.sae.org//j1939_dl/ for details5532Switch Backlight Illumination Brightness Percent
53248See http://subs.sae.org//j1939_dl/ for details6820Switch Indication Illumination Brightness Percent
53504See http://subs.sae.org//j1939_dl/ for details1732Level Preset Front Axle Left
53504See http://subs.sae.org//j1939_dl/ for details1757Level Preset Front Axle Right
53504See http://subs.sae.org//j1939_dl/ for details1758Level Preset Rear Axle Left
53504See http://subs.sae.org//j1939_dl/ for details1735Level Preset Rear Axle Right
53760See http://subs.sae.org//j1939_dl/ for details2984Automatic traction help (load transfer)
53760See http://subs.sae.org//j1939_dl/ for details1749Kneeling Request Left Side
53760See http://subs.sae.org//j1939_dl/ for details1748Kneeling Request Right Side
53760See http://subs.sae.org//j1939_dl/ for details1747Kneeling Control Mode Request
53760See http://subs.sae.org//j1939_dl/ for details1751Nominal Level Request Front Axle
53760See http://subs.sae.org//j1939_dl/ for details1750Nominal Level Request Rear Axle
53760See http://subs.sae.org//j1939_dl/ for details1753Level Control Mode Request
53760See http://subs.sae.org//j1939_dl/ for details1752Lift Axle 1 Position Command
53760See http://subs.sae.org//j1939_dl/ for details1828Lift Axle 2 Position Command
53760See http://subs.sae.org//j1939_dl/ for details1718Damper Stiffness Request Front Axle
53760See http://subs.sae.org//j1939_dl/ for details1719Damper Stiffness Request Rear Axle
53760See http://subs.sae.org//j1939_dl/ for details1720Damper Stiffness Request Lift / Tag Axle
53760See http://subs.sae.org//j1939_dl/ for details1830Kneeling Command - Front Axle
53760See http://subs.sae.org//j1939_dl/ for details1829Kneeling Command - Rear Axle
53760See http://subs.sae.org//j1939_dl/ for details3215Prohibit air suspension control
53760See http://subs.sae.org//j1939_dl/ for details5293Allow Level Control During Braking Command
53760See http://subs.sae.org//j1939_dl/ for details5295Speed Dependent Level Control Request
53760See http://subs.sae.org//j1939_dl/ for details5274Prohibit Automatic Air Suspension Control
53760See http://subs.sae.org//j1939_dl/ for details5433Memory level request
54016See http://subs.sae.org//j1939_dl/ for details1634Calibration Verification NumberView
54016See http://subs.sae.org//j1939_dl/ for details1635Calibration IdentificationView
54272See http://subs.sae.org//j1939_dl/ for details1596Security Entity LengthView
54272See http://subs.sae.org//j1939_dl/ for details1479Security Entity TypeView
54272See http://subs.sae.org//j1939_dl/ for details1597Data Security ParameterView
54528See http://subs.sae.org//j1939_dl/ for details1603Adjust seconds
54528See http://subs.sae.org//j1939_dl/ for details1604Adjust minutes
54528See http://subs.sae.org//j1939_dl/ for details1605Adjust hours
54528See http://subs.sae.org//j1939_dl/ for details1606Adjust month
54528See http://subs.sae.org//j1939_dl/ for details1607Adjust day
54528See http://subs.sae.org//j1939_dl/ for details1608Adjust year
54528See http://subs.sae.org//j1939_dl/ for details1609Adjust local minute offset
54528See http://subs.sae.org//j1939_dl/ for details1610Adjust local hour offset
54784See http://subs.sae.org//j1939_dl/ for details1652Boot Load DataView
55040See http://subs.sae.org//j1939_dl/ for details1650Number of Occurrences of Raw Binary DataView
55040See http://subs.sae.org//j1939_dl/ for details1651Raw Binary DataView
55040See http://subs.sae.org//j1939_dl/ for details1651Raw Binary DataView
55296See http://subs.sae.org//j1939_dl/ for details1649Length/Number AllowedView
55296See http://subs.sae.org//j1939_dl/ for details1646Status (for DM 15)View
55296See http://subs.sae.org//j1939_dl/ for details1648Error Indicator/EDC ParameterView
55296See http://subs.sae.org//j1939_dl/ for details1647EDCP ExtensionView
55296See http://subs.sae.org//j1939_dl/ for details1599SeedView
55552See http://subs.sae.org//j1939_dl/ for details1640Length/Number RequestedView