PGN65035
PG LabelTractor control mode command
PG AcronymIRC
PG NotesAs of the third edition of ISO 11783-7, the Tractor control mode command message described in this section is deprecated and shall not be used for new designs.
Task controller or implement to Tractor ECU message.
Two commands are grouped within this single message. Many of the command modes are mutually exclusive and are grouped accordingly
Pgn NotesNot set
EDP0
DP0
PF254
PS11
MultipacketNo
Transmission RateDefault is 100 ms, maximum is 10 ms for doing closed-loop cruise control. For setting slip control functions, a repetition rate of 1 s in 10 s and on a change of state is required. If there is no update after 15 s, the Tractor ECU will default to no-slip control
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit2.4
PG DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked SPNs

Displaying 1-2 of 2 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
5204Tractor control mode command number 11.4532 states/5 bit0View
5204Tractor control mode command number 22.4532 states/5 bit0View