PGN | 65035 |
---|---|
PG Label | Tractor control mode command |
PG Acronym | IRC |
PG Notes | As of the third edition of ISO 11783-7, the Tractor control mode command message described in this section is deprecated and shall not be used for new designs. Task controller or implement to Tractor ECU message. Two commands are grouped within this single message. Many of the command modes are mutually exclusive and are grouped accordingly |
Pgn Notes | Not set |
EDP | 0 |
DP | 0 |
PF | 254 |
PS | 11 |
Multipacket | No |
Transmission Rate | Default is 100 ms, maximum is 10 ms for doing closed-loop cruise control. For setting slip control functions, a repetition rate of 1 s in 10 s and on a change of state is required. If there is no update after 15 s, the Tractor ECU will default to no-slip control |
PG Data Length | 8 |
Default Priority | 3 |
PG Reference | Not set |
Sp Start Bit | 2.4 |
PG Document | ISO 11783-7 |
PG Created or Modified Date | Not set |
PG SP Mapping Created/Mod. Date | Not set |