List DDEntity

Version: 2021051201
Displaying 601-647 of 647 results.
605 - Actual Tramline Condensed Work State (49-64) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 49 to 64 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
606 - Actual Tramline Condensed Work State (65-80) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 65 to 80 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
607 - Actual Tramline Condensed Work State (81-96) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 81 to 96 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
608 - Actual Tramline Condensed Work State (97-112) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 97 to 112 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
609 - Actual Tramline Condensed Work State (113-128) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 113 to 128 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
610 - Actual Tramline Condensed Work State (129-144) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 129 to 144 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
611 - Actual Tramline Condensed Work State (145-160) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 145 to 160 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
612 - Actual Tramline Condensed Work State (161-176) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 161 to 176 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
613 - Actual Tramline Condensed Work State (177-192) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 177 to 192 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
614 - Actual Tramline Condensed Work State (193-208) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 193 to 208 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
615 - Actual Tramline Condensed Work State (209-224) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 209 to 224 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
616 - Actual Tramline Condensed Work State (225-240) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 225 to 240 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
617 - Actual Tramline Condensed Work State (241-256) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 241 to 256 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
618 - Setpoint Tramline Condensed Work State (17-32) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 17 to 32 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
619 - Setpoint Tramline Condensed Work State (33-48) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 33 to 48 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
620 - Setpoint Tramline Condensed Work State (49-64) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 49 to 64 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
621 - Setpoint Tramline Condensed Work State (65-80) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 65 to 80 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
622 - Setpoint Tramline Condensed Work State (81-96) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 81 to 96 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
623 - Setpoint Tramline Condensed Work State (97-112) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 97 to 112 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
624 - Setpoint Tramline Condensed Work State (113-128) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 113 to 128 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
625 - Setpoint Tramline Condensed Work State (129-144) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 129 to 144 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
626 - Setpoint Tramline Condensed Work State (145-160) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 145 to 160 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
627 - Setpoint Tramline Condensed Work State (161-176) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 161 to 176 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
628 - Setpoint Tramline Condensed Work State (177-192) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 177 to 192 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
629 - Setpoint Tramline Condensed Work State (193-208) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 193 to 208 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
630 - Setpoint Tramline Condensed Work State (209-224) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 209 to 224 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
631 - Setpoint Tramline Condensed Work State (225-240) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 225 to 240 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
632 - Setpoint Tramline Condensed Work State (241-256) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 241 to 256 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
633 - Setpoint Volume per distance Application Rate View details | Request changes
Definition: Setpoint Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
634 - Actual Volume per distance Application Rate View details | Request changes
Definition: Actual liquid application based on distance travelled, e.g. in vineyards, orchards.
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
635 - Default Volume per distance Application Rate View details | Request changes
Definition: Default Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
636 - Minimum Volume per distance Application Rate View details | Request changes
Definition: Minimum Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
637 - Maximum Volume per distance Application Rate View details | Request changes
Definition: Maximum Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 5 - Fertilizer
6 - Sprayers
7 - Harvesters
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
638 - Setpoint Tire Pressure View details | Request changes
Definition: Setpoint Tire Pressure to adjust the pressure of the Tire at the point of dispensing.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
639 - Actual Tire Pressure View details | Request changes
Definition: Actual Tire Pressure is the measured pressure in the tire during operation.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
640 - Default Tire Pressure View details | Request changes
Definition: Default Tire Pressure in the tire during operation.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
641 - Minimum Tire Pressure View details | Request changes
Definition: Minimum Tire Pressure in the tire at the time of operation
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
642 - Maximum Tire Pressure View details | Request changes
Definition: Maximum Tire Pressure in the tire during operation
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
32768 - Maximum Droplet Size View details | Request changes
Definition: Definition: The maximum droplet size the system can produce. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
36864 - Minimum Droplet Size View details | Request changes
Definition: The minimum droplet size the system can produce. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
40960 - Default Droplet Size View details | Request changes
Definition: The default droplet size the system is producing. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
17 - Sensor System
Bit Resolution: 1
45056 - Actual Droplet Size View details | Request changes
Definition: The actual droplet size the system is producing. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
49152 - Setpoint Droplet Size View details | Request changes
Definition: The setpoint for droplet size. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
57342 - PGN Based Data View details | Request changes
Definition: This DDI is used in the XML files to identify PGN based data.
Unit Symbol: n.a.
Typically used by Device Class(es): 0 - Non-specific system
1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
12 - Farmyard Work
13 - Powered Auxilary Units
14 - Special Crops
15 - Municipal Work
Bit Resolution: 1
57343 - Request Default Process Data View details | Request changes
Definition: Request Default Process Data. This DDE is the highest ISO assigned entity. The range above this number is reserved for manufacture specific DDE's.
Unit Symbol: n.a.
Typically used by Device Class(es): - Not Assigned
Bit Resolution: 1
57344 - 65534 Proprietary DDI Range View details | Request changes
Definition: Manufacturer proprietary definitions
Unit Symbol: n.a.
Typically used by Device Class(es): - Not Assigned
Bit Resolution: 0
65535 - Reserved View details | Request changes
Definition: Reserved
Unit Symbol: n.a.
Typically used by Device Class(es): - Not Assigned
Bit Resolution: 0