List DDEntity

Version: 2024041701
Displaying 601-700 of 723 results.
604 - Actual Tramline Condensed Work State (33-48) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 33 to 48 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
605 - Actual Tramline Condensed Work State (49-64) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 49 to 64 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
606 - Actual Tramline Condensed Work State (65-80) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 65 to 80 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
607 - Actual Tramline Condensed Work State (81-96) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 81 to 96 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
608 - Actual Tramline Condensed Work State (97-112) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 97 to 112 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
609 - Actual Tramline Condensed Work State (113-128) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 113 to 128 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
610 - Actual Tramline Condensed Work State (129-144) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 129 to 144 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
611 - Actual Tramline Condensed Work State (145-160) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 145 to 160 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
612 - Actual Tramline Condensed Work State (161-176) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 161 to 176 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
613 - Actual Tramline Condensed Work State (177-192) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 177 to 192 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
614 - Actual Tramline Condensed Work State (193-208) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 193 to 208 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
615 - Actual Tramline Condensed Work State (209-224) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 209 to 224 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
616 - Actual Tramline Condensed Work State (225-240) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 225 to 240 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
617 - Actual Tramline Condensed Work State (241-256) View details | Request changes
Definition: Combination of the Actual States of individual Tramline Valves number 241 to 256 into a single Actual Tramline State of their parent DeviceElement. The Actual Tramline Condensed Work State contains the child element Actual Tramline Work States, in the driving direction from left to right, where the leftmost child element Actual Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Actual Tramline Work State is represented by 2 bits and defined as: 00 = disabled/off, 01 = enabled/on, 10 = error indicator, 11 = undefined/not installed. In total 16 child device element Actual Tramline Work States can be contained in one Actual Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Actual Tramline Work States are available, then the unused bits shall be set to value 11 (not installed).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
618 - Setpoint Tramline Condensed Work State (17-32) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 17 to 32 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
619 - Setpoint Tramline Condensed Work State (33-48) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 33 to 48 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
620 - Setpoint Tramline Condensed Work State (49-64) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 49 to 64 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
621 - Setpoint Tramline Condensed Work State (65-80) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 65 to 80 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
622 - Setpoint Tramline Condensed Work State (81-96) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 81 to 96 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
623 - Setpoint Tramline Condensed Work State (97-112) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 97 to 112 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
624 - Setpoint Tramline Condensed Work State (113-128) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 113 to 128 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
625 - Setpoint Tramline Condensed Work State (129-144) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 129 to 144 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
626 - Setpoint Tramline Condensed Work State (145-160) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 145 to 160 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
627 - Setpoint Tramline Condensed Work State (161-176) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 161 to 176 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
628 - Setpoint Tramline Condensed Work State (177-192) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 177 to 192 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
629 - Setpoint Tramline Condensed Work State (193-208) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 193 to 208 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
630 - Setpoint Tramline Condensed Work State (209-224) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 209 to 224 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
631 - Setpoint Tramline Condensed Work State (225-240) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 225 to 240 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
632 - Setpoint Tramline Condensed Work State (241-256) View details | Request changes
Definition: The Setpoint Tramline Condensed Work State DDIs are the control command counterparts to the Actual Tramline Condensed Work States DDIs. The value is a combination of the Setpoint Tramline Valve Work States of individual Tramline Valves number 241 to 256 into a single Setpoint Tramline Condensed Work State of their parent DeviceElement. The Setpoint Tramline Condensed Work State contains the child element Setpoint Tramline Work States, in the driving direction from left to right, where the leftmost child element Setpoint Tramline Work State are the 2 lowest significant bits of the Process Data Value. Each child device elements Setpoint Work State is represented by 2 bits and defined as: 00 = disable/off, 01 = enable/on, 10 = error indicator, 11 = no change. In total 16 child device element Setpoint Tramline Work States can be contained in one Setpoint Tramline Condensed Work State of their parent DeviceElement. If less than 16 child device element Setpoint Tramline Work States are available, then the unused bits shall be set to value 11 (no change).
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
633 - Setpoint Volume per distance Application Rate View details | Request changes
Definition: Setpoint Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
634 - Actual Volume per distance Application Rate View details | Request changes
Definition: Actual liquid application based on distance travelled, e.g. in vineyards, orchards.
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
635 - Default Volume per distance Application Rate View details | Request changes
Definition: Default Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
636 - Minimum Volume per distance Application Rate View details | Request changes
Definition: Minimum Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
637 - Maximum Volume per distance Application Rate View details | Request changes
Definition: Maximum Application Rate specified as volume per distance
Unit Symbol: ml/m
Typically used by Device Class(es): 5 - Fertilizer
6 - Sprayers
7 - Harvesters
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 0,001
638 - Setpoint Tire Pressure View details | Request changes
Definition: Setpoint Tire Pressure to adjust the pressure of the Tire at the point of dispensing.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
639 - Actual Tire Pressure View details | Request changes
Definition: Actual Tire Pressure is the measured pressure in the tire during operation.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
640 - Default Tire Pressure View details | Request changes
Definition: Default Tire Pressure in the tire during operation.
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
641 - Minimum Tire Pressure View details | Request changes
Definition: Minimum Tire Pressure in the tire at the time of operation
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
642 - Maximum Tire Pressure View details | Request changes
Definition: Maximum Tire Pressure in the tire during operation
Unit Symbol: Pa
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 0,1
643 - Actual Tire Temperature View details | Request changes
Definition: Actual Tire Temperature is the measured temperature in the tire during operation.
Unit Symbol: mK
Typically used by Device Class(es): 1 - Tractor
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
11 - Transport / Trailers
25 - Slurry Applicators
Bit Resolution: 1
644 - Binding Method View details | Request changes
Definition: Specification of the method used to bind bales. The value definitions represent a set of flags. The flag values are: 0 = unknown (default) 1 = Mesh 2 = Twine 3 = Film 4 = Twine & Mesh 5 = Twine & Film 6 and higher are are reserved for future assignments
Unit Symbol: n.a.
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
645 - Last Bale Number of Knives View details | Request changes
Definition: Number of cutting knives used in the most recently produced bale
Unit Symbol: #
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
646 - Last Bale Binding Twine Consumption View details | Request changes
Definition: Binding twine consumption in the most recently produced bale
Unit Symbol: mm
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
647 - Last Bale Binding Mesh Consumption View details | Request changes
Definition: Binding mesh consumption in the most recently produced bale
Unit Symbol: mm
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
648 - Last Bale Binding Film Consumption View details | Request changes
Definition: Binding film consumption in the most recently produced bale
Unit Symbol: mm
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
649 - Last Bale Binding Film Stretching View details | Request changes
Definition: Binding film stretching in the most recently produced bale
Unit Symbol: %
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 0,001
650 - Last Bale Wrapping Film Width View details | Request changes
Definition: Wrapping film width in the most recently produced bale
Unit Symbol: mm
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
651 - Last Bale Wrapping Film Consumption View details | Request changes
Definition: Wrapping film consumption in the most recently produced bale
Unit Symbol: mm
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
652 - Last Bale Wrapping Film Stretching View details | Request changes
Definition: Wrapping film stretching in the most recently produced bale
Unit Symbol: %
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 0,001
653 - Last Bale Wrapping Film Overlap Percentage View details | Request changes
Definition: Wrapping film overlap percentage in the most recently produced bale
Unit Symbol: %
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 0,001
654 - Last Bale Wrapping Film Layers View details | Request changes
Definition: Wrapping film layers in the most recently produced bale
Unit Symbol: #
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
655 - Electrical Apparent Soil Conductivity View details | Request changes
Definition: Electrical conductivity also called the EC-Value. For materials this is a constant. For material mixes like soil you can measure a apparent conductivity, which gives information about the soil conditions.
Unit Symbol: mS/m
Typically used by Device Class(es): 2 - Primary Soil Tillage
3 - Secondary Soil Tillage
17 - Sensor System
Bit Resolution: 0,1
656 - SC Actual Turn On Time View details | Request changes
Definition: Definition: The Section Control Actual Turn On Time defines the overall time lapse between the moment the TC client sends the actual Section state and the moment this section is physically turned on and the product is applied. The working set may support this DDE as an optional feature to provide the possibility to store the time settings direct on the device to make the settings available after a power cycle. Therefore this DDE needs always to be settable by the TC and shall not be used to change any working set system behavior. The DDI shall support the On Change trigger so that the TC is able to get informed when the value gets changed by the Working Set Master. The TC shall activate this trigger when using the DDI.
Unit Symbol: not defined
Typically used by Device Class(es): 1 - Tractor
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Bit Resolution: 1
657 - SC Actual Turn Off Time View details | Request changes
Definition: The Section Control Actual Turn Off Time defines the overall time lapse between the moment the TC client sends the actual Section state and the moment this section is physically turned off and the product is stopped from being applied. The working set may support this DDE as an optional feature to provide the possibility to store the time settings direct on the device to make the settings available after a power cycle. Therefore this DDE needs always to be settable by the TC and shall not be used to change any working set system behavior. The DDI shall support the On Change trigger so that the TC is able to get informed when the value gets changed by the Working Set Master. The TC shall activate this trigger when using the DDI.
Unit Symbol: not defined
Typically used by Device Class(es): 1 - Tractor
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
Bit Resolution: 1
658 - Actual CO2 equivalent specified as mass per area View details | Request changes
Definition: Actual CO2 equivalent specified as mass per area
Unit Symbol: mg/m²
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 1
659 - Actual CO2 equivalent specified as mass per time View details | Request changes
Definition: Actual CO2 equivalent specified as mass per time
Unit Symbol: mg/s
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
25 - Slurry Applicators
26 - Feeder / Mixer
Bit Resolution: 1
660 - Actual CO2 equivalent specified as mass per mass View details | Request changes
Definition: Actual CO2 equivalent specified as mass per mass (application rate)
Unit Symbol: mg/kg
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 1
661 - Actual CO2 equivalent specified as mass per yield View details | Request changes
Definition: Actual CO2 equivalent specified as mass per yield mass
Unit Symbol: mg/kg
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
19 - Timber Harvesters
Bit Resolution: 1
662 - Actual CO2 equivalent specified as mass per volume View details | Request changes
Definition: Actual CO2 equivalent specified as mass per volume
Unit Symbol: mg/l
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
25 - Slurry Applicators
Bit Resolution: 1
663 - Actual CO2 equivalent specified as mass per count View details | Request changes
Definition: Actual CO2 equivalent specified as mass per count
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
7 - Harvesters
8 - Root Harvester
19 - Timber Harvesters
Bit Resolution: 1
664 - Total CO2 equivalent View details | Request changes
Definition: Accumulated CO2 equivalent specified as mass in kilogram [kg]
Unit Symbol: kg
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
25 - Slurry Applicators
26 - Feeder / Mixer
Bit Resolution: 1
665 - Lifetime total CO2 equivalent View details | Request changes
Definition: Entire Lifetime CO2 equivalent specified as mass in kilogram [kg]
Unit Symbol: kg
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
19 - Timber Harvesters
20 - Forwarders
21 - Timber loaders
22 - Timber Processing Machines
25 - Slurry Applicators
26 - Feeder / Mixer
Bit Resolution: 1
666 - Working Direction View details | Request changes
Definition: This DDI defines the intended Working Direction in the field and also defines the numbering of the Bouts.
Unit Symbol: not defined
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
667 - Distance between Guidance Track Number 0R and 1 View details | Request changes
Definition: This DDI defines the distance between tracks 0R and 1.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
668 - Distance between Guidance Track Number 0R and 0L View details | Request changes
Definition: This DDI defines the distance between tracks 0R and 0L.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
669 - Bout Track Number Shift View details | Request changes
Definition: This DDI defines the amount of tramlines the Tramline pattern is to be shifted.
Unit Symbol: not defined
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
670 - Tramline Crop protection/fertilization Working Width View details | Request changes
Definition: Working Width of the Crop protection/fertilization vehicle which will drive on the tramline tracks.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
671 - Tramline Tire Width View details | Request changes
Definition: Width of the largest tire which should fit on the Tramline Track.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
672 - Tramline Wheel Distance View details | Request changes
Definition: Distance between the centres of the Wheels of the Crop protection/fertilization vehicle.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
673 - Tramline Irrigation Working Width View details | Request changes
Definition: The Working Width of the Irrigation system is the Distance between the single Tramline Tracks for the Irrigation system.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
674 - Tramline Irrigation Tire Width View details | Request changes
Definition: Width of the largest tire which should fit on the Tramline Track.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
675 - Tramline Irrigation Wheel Distance View details | Request changes
Definition: Distance between the centre of the Wheels of the Irrigation system.
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
Bit Resolution: 1
676 - Last Bale Binding Mesh Layers View details | Request changes
Definition: Binding mesh layers in the most recently produced bale
Unit Symbol: #
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
677 - Last Bale Binding Film Layers View details | Request changes
Definition: Binding film layers in the most recently produced bale
Unit Symbol: #
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
678 - Last Bale Binding Twine Layers View details | Request changes
Definition: Binding twine layers in the most recently produced bale
Unit Symbol: #
Typically used by Device Class(es): 7 - Harvesters
9 - Forage harvester
Bit Resolution: 1
679 - Crop Contamination Total Mass View details | Request changes
Definition: Accumulated mass of contamination in yield by dirt or foreign material as a total counter
Unit Symbol: kg
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1
680 - Crop Contamination Lifetime Total Mass View details | Request changes
Definition: Accumulated mass of contamination in yield by dirt or foreign material as a lifetime counter
Unit Symbol: kg
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1
681 - Film bale Total Count View details | Request changes
Definition: The total number of foil or film bound product units for which foil or film binding method was used during operation.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
682 - Mesh bale Total Count View details | Request changes
Definition: The total number of mesh bound product units for which mesh binding method was used during operation.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
683 - Twine bale Total Count View details | Request changes
Definition: The total number of twine bound product units for which twine binding method was used during operation.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
684 - Wrapping Film bale Total Count View details | Request changes
Definition: The total number of wrapping units for which wrapping film binding method was used during operation.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
685 - Lifetime Film Bale Total Count View details | Request changes
Definition: Total number of film or foil bound product units for which film or foil binding method was used during operation, of a device lifetime.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
686 - Lifetime Mesh Bale Total Count View details | Request changes
Definition: Total number of mesh bound product units for which mesh binding method was used during operation, of a device lifetime
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
687 - Lifetime Twine Bale Total Count View details | Request changes
Definition: Total number of twine bound product units for which Twine binding method was used during operation, of a device lifetime.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
688 - Lifetime Wrapping Film Bale Total Count View details | Request changes
Definition: Total number of wrapping units for which wrapping film binding method was used during operation, of a device lifetime.
Unit Symbol: #
Typically used by Device Class(es): 9 - Forage harvester
Bit Resolution: 1
689 - Effective Total Electrical Battery Energy Consumption View details | Request changes
Definition: Accumulated total electrical battery energy consumption in working position.
Unit Symbol: kWh
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Bit Resolution: 0,001
690 - Ineffective Total Electrical Battery Energy Consumption View details | Request changes
Definition: Accumulated total electrical battery energy consumption in non working position.
Unit Symbol: kWh
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Bit Resolution: 0,001
691 - Instantaneous Electrical Battery Energy Consumption per Time View details | Request changes
Definition: Electrical battery energy consumption per time
Unit Symbol: W
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Bit Resolution: 1
692 - Instantaneous Electrical Battery Energy Consumption per Area View details | Request changes
Definition: Electrical battery energy consumption per area
Unit Symbol: kWh/m²
Typically used by Device Class(es): 1 - Tractor
2 - Primary Soil Tillage
3 - Secondary Soil Tillage
4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
7 - Harvesters
8 - Root Harvester
9 - Forage harvester
10 - Irrigation
11 - Transport / Trailers
Bit Resolution: 1,0E-5
32768 - Maximum Droplet Size View details | Request changes
Definition: Definition: The maximum droplet size the system can produce. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
32769 - Maximum Crop Grade Diameter View details | Request changes
Definition: Maximum crop diameter in mm, measured with crop specific methods
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Bit Resolution: 0,001
32770 - Maximum Crop Grade Length View details | Request changes
Definition: Maximum crop length in mm, measured with crop specific methods
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Bit Resolution: 0,001
32771 - Maximum Crop Contamination Mass per Area View details | Request changes
Definition: Maximum absolut mass of contamination in yield by dirt or foreign material per area
Unit Symbol: mg/m²
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1
32772 - Maximum Crop Contamination Mass per Time View details | Request changes
Definition: Maximum mass of contamination in yield by dirt or foreign material per time
Unit Symbol: mg/s
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1
32773 - Maximum Crop Conditioning Intensity View details | Request changes
Definition: The maximum level of crop conditioning intensity, expressed as a percentage of the maximum level offered by the implement.
Unit Symbol: %
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
9 - Forage harvester
14 - Special Crops
15 - Municipal Work
Bit Resolution: 0,01
36864 - Minimum Droplet Size View details | Request changes
Definition: The minimum droplet size the system can produce. Defined as: 0 = Unknown, 1 = Extremely Fine - XF, 2 = Very Fine - VF, 3 = Fine - F, 4 = Medium - M, 5 = Coarse - C, 6 = Very Coarse - VC, 7 = Extremely Coarse - XC, 8 = Ultra Coarse - UC, 9-254 = Reserved, 255 = No Droplet Size Available.
Unit Symbol: n.a.
Typically used by Device Class(es): 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Bit Resolution: 1
36865 - Minimum Crop Grade Diameter View details | Request changes
Definition: Minimum crop diameter in mm, measured with crop specific methods
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Bit Resolution: 0,001
36866 - Minimum Crop Grade Length View details | Request changes
Definition: Minimum crop length in mm, measured with crop specific methods
Unit Symbol: mm
Typically used by Device Class(es): 4 - Planters /Seeders
7 - Harvesters
8 - Root Harvester
14 - Special Crops
17 - Sensor System
Bit Resolution: 0,001
36867 - Minimum Crop Contamination Mass per Area View details | Request changes
Definition: Minimum absolut mass of contamination in yield by dirt or foreign material per area
Unit Symbol: mg/m²
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1
36868 - Minimum Crop Contamination Mass per Time View details | Request changes
Definition: Minimum mass of contamination in yield by dirt or foreign material per time
Unit Symbol: mg/s
Typically used by Device Class(es): 7 - Harvesters
8 - Root Harvester
Bit Resolution: 1