PGN65040
PG LabelAuxiliary valve 0 estimated flow
PG AcronymAV00EF
PG NotesMessage that provides the estimated flow of auxiliary valve number 0.
Pgn NotesThis valve is used for “power beyond” control.
EDP0
DP0
PF254
PS16
MultipacketNo
Transmission Rate100 ms
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit3.7
PG DocumentISO 11783-7
PG Created or Modified Date2011-02-03
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-7 of 7 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1901Auxiliary valve 0 extend port estimated flow18 bits1 %/bit-125View
1902Auxiliary valve 0 retract port estimated flow28 bits1 %/bit-125View
1903Auxiliary valve number 0 valve state3.14 bits16 states/4 bit0View
1910Auxiliary valve 0 fail safe mode3.72 bits4 states/2 bit0View
5161Auxiliary valve number 0 estimated flow limit status4.63 bits8 states/3 bit0View
5800Auxiliary valve 0 exit/reason code5.16 bits64 states/6 bit0View
9732Auxiliary valve 0 estimated flow (high resolution)7-816 bits0.004 %/bit-125View